Half Cycle Programming - Tabor Electronics 5064 User Manual

50 / 100 / 200 ms/s four channel arbitrary waveform generator
Table of Contents

Advertisement

Half Cycle
Programming
AUXiliary:HALFcycle:DELay<delay>(?)
Description
This command will program the interval of which the output idles between half cycles. The idle level is
normally 0 V except if programmed otherwise with the volt:offs command.
Parameters
Name
Range
<delay>
200e-9 to 20
Response
The 2074 will return the half cycle delay value in units of seconds.
AUXiliary:HALFcycle:DCYCle<duty_cycle>(?)
Description
This command will program the duty cycle of the square waveform when the half cycle square shape is
selected. Note that this command has no effect on the standard square wave duty cycle.
Parameters
Name
Range
<duty_cycle>
0 to 99.99
Response
The 2074 will return the square wave duty cycle value in units of percent.
AUXiliary:HALFcycle:FREQuency<freq>(?)
Description
This command programs the frequency of the half cycle waveforms in units of hertz (Hz). It has no affect on
the frequency of other waveform functions.
Use the following command for programming the half cycle
functions and their associated parameters. There are three half
cycle functions: Sine, Triangle and Square. The specifications and
limitations of the half cycle functions are specified in Appendix A.
Type
Default
Numeric
1e-6
Type
Default
Numeric
50
Description
Will set the delay time interval between half cycles in
units of seconds.
Description
Will set the delay time interval between half cycles in
units of seconds.
E