Sequence Parameters - Tabor Electronics 5064 User Manual

50 / 100 / 200 ms/s four channel arbitrary waveform generator
Table of Contents

Advertisement

2074
User Manual
1
3-40
waveform will cycle twice through the same segment before
transitioning to the next link.
Adv – This field is a special code that is used in conjunction with
the mixed advance mode. This bit flags the 2074 if the selected link
is continuous or stepped. Information on the Mixed sequence
advance mode is given later. "0" flags continuous, "1" flags stepped.
Assuming that you already downloaded waveforms, created and
downloaded sequence table, you can proceed now with the
following description how to set the 2074 to output sequenced
waveforms.
Refer to Figure 3-18 and use the following description to learn how
to output sequenced waveforms and how to program sequence
parameters. To select Sequenced waveforms as the output
waveform type press Waveforms, then Sequenced. The screen as
shown in Figure 3-18 will display and the output will already
generate arbitrary waveforms. Note the channel you are currently
program and make sure the icon at the upper right corner agrees
with your required programming sequence.
Use the following procedure to modify the parameters that are
associated with the Sequenced waveforms function:
1. Press the soft key next to the required parameter to display the
edit field
2. Punch in the value using the numeric keypad. Be careful not to
exceed parameter limits while you key the numbers
3. Select and press a suffix
4. Press Enter to lock in the new value