4 Repair
4.3.2 Refitting the complete cable harness
Continued
Refitting the cable harness in the lower arm and armhouse
Use this procedure to refit the cable harness in the lower arm and armhouse.
1
2
3
4
Continues on next page
230
Tip
Before starting this procedure, first refit the cable harness in the frame and base.
See:
Refitting the complete cable harness on page 217
Refitting the complete cable harness on page 217
Action
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
to the robot, before entering the robot
working area.
Secure the brackets on the lower arm.
Refit the cable straps securing the cable
harness to the lower arm.
Push the cable harness carefully into the
armhouse.
© Copyright 2013-2018 ABB. All rights reserved.
Note
B
A
xx0900000020
Parts:
A: Bracket, lower arm
B: Bracket, lower arm
C: Bracket, armhouse
D: Cable bracket
See the figure in:
Location of the cable harness on
page 218
(Cable harness, lower arm)
Product manual - IRB 4600 Foundry Prime