Configuring PVLAN

1. Configure VLAN tagging/trunk mode for ports.
2. Create a VLAN and define the protocol type(s) supported by the VLAN.
3. Configure the priority value for the protocol.
4. Add member ports for this PVLAN.
5. Enable the PVLAN.
6. Verify PVLAN operation.  
168
G8264 Application Guide for ENOS 8.4
Follow this procedure to configure a Protocol‐based VLAN (PVLAN).
RS G8264(config)# interface port 1, 2
RS G8264(config­if)# switchport mode trunk
RS G8264(config­if)# exit
RS G8264(config)# vlan 2
RS G8264(config­vlan)# protocol­vlan 1 frame­type ether2 0800
RS G8264(config­vlan)# protocol­vlan 1 priority 2
RS G8264(config­vlan)# protocol­vlan 1 member 1, 2
Note: If VLAN tagging is turned on and the port being added to the VLAN has a 
different default VLAN (PVID/Native VLAN), you will be asked to confirm 
changing the PVID to the current VLAN.
RS G8264(config­vlan)# protocol­vlan 1 enable
RS G8264(config­vlan)# exit
RS G8264(config)# show vlan
VLAN            Name            Status            Ports
­­­­  ­­­­­­­­­­­­­­­­­­­­­­­­  ­­­­­­  ­­­­­­­­­­­­­­­­­­­­­­­­­
1     Default VLAN              ena      1­48, XGE1­XGE4
2     VLAN 2                    ena      1 2
PVLAN  Protocol  FrameType 
­­­­­  ­­­­­­­­  ­­­­­­­­­­  ­­­­­­­­­  ­­­­­­­­  ­­­­­­­  ­­­­­­­­­­­
2      1         Ether2      0800       2         enabled  1 2
PVLAN      PVLAN­Tagged Ports
­­­­­  ­­­­­­­­­­­­­­­­­­­­­­­­­­­
none   none
EtherType  Priority  Status      Ports