3. Configure port as UFP. 
4. Configure virtual port. 
5. Configure vPort tunnel mode. 
6. Configure vPort default VLAN. 
7. Specify QoS parameters for the vPort. 
8. Enable the vPort. 
9. Configure tagging on port 2. 

Example 5: FCoE Mode

1. Enable CEE. Configure port 1 as a UFP server port. 
2. Enable CEE. 
© Copyright Lenovo 2016
G8264(config)# ufp port 1 enable
Warning: "Tagging/Trunk­mode" is enabled on UFP port 1
G8264(config)# ufp port 1 vport 1
G8264(config_ufp_vport)# network mode tunnel
G8264(config_ufp_vport)# network default­vlan 4000
G8264(config_ufp_vport)# qos bandwidth min 25           (in percentage)
G8264(config_ufp_vport)# qos bandwidth max 100          (in percentage)
G8264(config_ufp_vport)# enable
G8264(config_ufp_vport)# exit
Note: Port 2 must be an upstream port.
G8264(config)# interface port 2
G8264(config­if)# tagpvid­ingress
G8264(config­if)# no vlan dot1q tag native 
G8264(config­if)# switchport access vlan 4000
G8264(config­if)# exit
Following is an example configuration of UFP vPorts in FCoE mode. 
G8264(config)# system server­ports port 1
G8264(config)# cee enable