Configuring VLAGs

214
G8264 Application Guide for ENOS 8.4
When configuring VLAG or making changes to your VLAG configuration, 
consider the following VLAG behavior:
When adding a static Mrouter on VLAG links, ensure that you also add it on the 
ISL link to avoid VLAG link failure. If the VLAG link fails, traffic cannot be 
recovered through the ISL. Also ensure you add the same static entry on the 
peer VLAG switch for VLAG ports.
If you have enabled VLAG on the switch, and you need to change the STP mode, 
ensure that you first disable VLAG and then change the STP mode.
When VLAG is enabled, you may see two root ports on the secondary VLAG 
switch. One of these will be the actual root port for the secondary VLAG switch 
and the other will be a root port synced with the primary VLAG switch.
The LACP key used must be unique for each VLAG in the entire topology. 
The STG to VLAN mapping on both VLAG peers must be identical.
The following parameters must be identically configured on the VLAG ports of 
both the VLAG peers:
VLANs
Native VLAN tagging
Native VLAN/PVID
STP mode
BPDU Guard setting
STP port setting
MAC aging timers
Static MAC entries
ACL configuration parameters
QoS configuration parameters