1. Configure IP interface 128 for out‐of‐band connection: 
2. Configure IP interface 1 for in‐band connection: 
3. Configure IP interface 2 for in‐band connection: 
4. Enable OpenFlow globally:
5. Configure OpenFlow in‐band management ports: 
6. Create OpenFlow switch instance 1 and add data ports: 
284
G8264 Application Guide for ENOS 8.4
RS G8264(config)# interface ip 128
RS G8264(config­ip­if)# ip address 172.20.100.1 255.255.0.0 enable
RS G8264(config­ip­if)# exit
RS G8264(config)# vlan 3000
RS G8264(config­vlan)# exit
RS G8264(config)# interface port 6
RS G8264(config­if)# switchport mode trunk
RS G8264(config­if)# switchport trunk allowed vlan 3000
RS G8264(config­if)# exit
RS G8264(config)# interface ip 1
RS G8264(config­ip­if)# ip address 172.21.100.1 255.255.0.0 enable
RS G8264(config­ip­if)# vlan 3000
RS G8264(config­ip­if)# exit
RS G8264(config)# vlan 4000
RS G8264(config­vlan)# exit
RS G8264(config)# interface port 6
RS G8264(config­if)# switchport mode trunk
RS G8264(config­if)# switchport trunk allowed vlan 4000
RS G8264(config­if)# exit
RS G8264(config)# interface ip 2
RS G8264(config­ip­if)# ip address 172.22.100.1 255.255.0.0 enable
RS G8264(config­ip­if)# vlan 4000
RS G8264(config­ip­if)# exit
RS G8264(config)# openflow enable
RS G8264(config)# openflow mgmtport 6,6(Switch can connect with the controllers via data 
Note: Step 5 is not required when the switch operates in default boot profile.
RS G8264(config)# openflow instance 1
RS G8264(config­openflow­instance)# member 17,18,19­25(Add data ports 17,18, and 
port 6 and 6, which are connected to the controller 
networks)
(Create OpenFlow instance 1)
data port range 19 through 25 as 
members of OpenFlow instance 1)