Configuring PVLAN

1. Configure VLAN tagging/trunk mode for ports.
2. Create a VLAN and define the protocol type(s) supported by the VLAN.
3. Configure the priority value for the protocol.
4. Add member ports for this PVLAN.
5. Enable the PVLAN.
6. Verify PVLAN operation.     
152
CN4093 Application Guide for N/OS 8.4
Follow this procedure to configure a Protocol‐based VLAN (PVLAN).
CN 4093(config)# interface port 1,2
CN 4093(config-if)# switchport mode trunk
CN 4093(config-if)# exit
CN 4093(config)# vlan 2
CN 4093(config-vlan)# protocol-vlan 1 frame-type ether2 0800
CN 4093(config-vlan)# protocol-vlan 1 priority 2
CN 4093(config-vlan)# protocol-vlan 1 member 1,2
Note: If VLAN tagging is turned on and the port being added to the VLAN has a 
different default VLAN (PVID/Native VLAN), you will be asked to confirm 
changing the PVID to the current VLAN.
CN 4093(config-vlan)# protocol-vlan 1 enable
CN 4093(config-vlan)# exit
CN 4093(config)# show vlan
VLAN
----
----------------------------
1
Default VLAN
2
VLAN 2
Primary
Secondary
-------
---------
PVLAN
Protocol
FrameType
-----
--------
---------
2
1
Ether2
PVLAN
PVLAN-Tagged Ports
-----
---------------------------
none
none
Name
Status MGT
------ --- -------------------------
ena
ena
Type
Ports
-------
----------------
EtherType
Priority
---------
--------
0800
2
Ports
dis
INTA2-EXT15 EXT19
dis
INTA1 INTA2
vPorts
------------------
Status
Ports
-------
--------------
enabled
INTA1 INTA2

Advertisement

Table of Contents
loading

Table of Contents