10. Add ports and virtual pipes to their vNIC groups: 
© Copyright Lenovo 2016
RS G8264(config)# vnic vnicgroup 1
RS G8264(vnic­group­config)# vlan 100 (Specify the VLAN)
RS G8264(vnic­group­config)# member 17.1(Add FCoE vNIC pipes to the group)
RS G8264(vnic­group­config)# member 18.1
RS G8264(vnic­group­config)# member 19.1
RS G8264(vnic­group­config)# member 20.1
RS G8264(vnic­group­config)# member 21.1
RS G8264(vnic­group­config)# member 22.1
RS G8264(vnic­group­config)# member 23.1
RS G8264(vnic­group­config)# member 24.1
RS G8264(vnic­group­config)# port 40
RS G8264(vnic­group­config)# failover (Configure failover)
RS G8264(vnic­group­config)# enable
RS G8264(vnic­group­config)# exit
RS G8264(config)# vnic vnicgroup 3
RS G8264(vnic­group­config)# vlan 103 (Specify the VLAN)
RS G8264(vnic­group­config)# member 17.3(Add FCoE vNIC pipes to the group)
RS G8264(vnic­group­config)# member 18.3
RS G8264(vnic­group­config)# member 19.3
RS G8264(vnic­group­config)# member 20.3
RS G8264(vnic­group­config)# member 21.3
RS G8264(vnic­group­config)# member 22.3
RS G8264(vnic­group­config)# member 23.3
RS G8264(vnic­group­config)# member 24.3
RS G8264(vnic­group­config)# port 39
RS G8264(vnic­group­config)# failover (Configure failover)
RS G8264(vnic­group­config)# enable
RS G8264(vnic­group­config)# exit
RS G8264(config)# vnic vnicgroup 4
RS G8264(vnic­group­config)# vlan 104 (Specify the VLAN)
RS G8264(vnic­group­config)# member 17.4(Add FCoE vNIC pipes to the group)
RS G8264(vnic­group­config)# member 18.4
RS G8264(vnic­group­config)# member 19.4
RS G8264(vnic­group­config)# member 20.4
RS G8264(vnic­group­config)# member 21.4
RS G8264(vnic­group­config)# member 22.4
RS G8264(vnic­group­config)# member 23.4
RS G8264(vnic­group­config)# member 24.4
RS G8264(vnic­group­config)# port 38
RS G8264(vnic­group­config)# failover (Configure failover)
RS G8264(vnic­group­config)# enable
RS G8264(vnic­group­config)# exit
Note: No additional configuration for vNIC pipes or vNIC groups is required for 
FCoE. However, for other networks connected to the switch, appropriate vNIC 
pipes and vNIC groups should be configured as normal, if desired.
(Select vNIC group)
(Add the uplink port to the group)
(Enable the vNIC group)
(Select vNIC group)
(Add the uplink port to the group)
(Enable the vNIC group)
(Select vNIC group)
(Add the uplink port to the group)
(Enable the vNIC group)
Chapter 19: Virtual NICs