2. Place FCoE ports into a VLAN supported by the FCF and CNAs (typically VLAN 
3. Turn CEE on.
4. Turn global FIP snooping on:
5. If using an Emulex CNA, disable automatic VLAN creation. 
6. Enable FIP snooping on FCoE ports, and set the desired FCF mode:
376
G8264 Application Guide for ENOS 8.4
1002):
RS G8264(config)# vlan 1002
RS G8264(config­vlan)# exit
RS G8264(config)# interface port 2,3
RS G8264(config­if)# switchport mode trunk
RS G8264(config­if)# switchport trunk allowed vlan add 1002
RS G8264(config­if)# exit
Note:
Placing ports into the VLAN (Step 2) after tagging is enabled (Step
to ensure that their port VLAN ID (PVID) is not accidentally changed.
RS G8264(config)# cee enable
Note: Turning CEE on will automatically change some 802.1p QoS and 802.3x 
standard flow control settings and menus (see "Turning CEE On or Off" on 
page
368).
RS G8264(config)# fcoe fips enable
RS G8264(config)# no fcoe fips automatic­vlan
RS G8264(config)# fcoe fips port 2 enable
RS G8264(config)# fcoe fips port 2 fcf­mode on
RS G8264(config)# fcoe fips port 3 enable
RS G8264(config)# fcoe fips port 3 fcf­mode off
Note: By default, FIP snooping is enabled on all ports and the FCF mode set for 
automatic detection. The configuration in this step is unnecessary, if default 
settings have not been changed, and is shown merely as a manual configuration 
example.
(Select a VLAN)
(Exit VLAN configuration mode)
(Add FCoE ports to the VLAN)
1) helps 
(Enable FIPS on port 2)
  (Set as FCF connection)
 (Enable FIPS on port 3)
 (Set as ENode connection)