Vnics For Fcoe On Emulex Virtual Fabric Adapter - Lenovo RackSwitch G8264 Application Manual

For lenovo enterprise network operating system 8.4
Hide thumbs Also See for RackSwitch G8264:
Table of Contents

Advertisement

vNICs for FCoE on Emulex Virtual Fabric Adapter

1. Disable FIP snooping automatic VLAN creation. 
2. Turn CEE on.
3. Turn global FIP snooping on:
4. Configure server ports to be used for FCoE. 
5. Enable VLAN tagging on FCoE ports. 
© Copyright Lenovo 2016
ENOS vNICs support FCoE (see Chapter
application, when using the Emulex Virtual Fabric Adapter, FCoE traffic is 
expected to occur only on vNIC pipe 2. In this case, the additional vNIC 
configuration for FCoE support is minimal.
Consider an example where the Fibre Channel network is connected to an FCoE 
Forwarder (FCF) (See "The FCoE Topology" on page
are server ports connected to an Emulex Virtual Fabric Adapter. Ports 38‐40 are the 
uplink ports for the vNIC groups.
The following steps are required as part of the regular FCoE configuration (see 
"FIP Snooping Configuration" on page
a. Disable the FIP Snooping automatic VLAN creation.
b. Disable FIP Snooping on all external ports not used for FCoE. FIP snooping 
should be enabled only on ports connected to an FCF or ENode.
c. Turn on CEE and FIP Snooping.
d. Manually configure the FCoE ports and VLAN: enable VLAN tagging on all 
FCoE ports, enable PVID tagging on ENode ports (only for Emulex CNA BE 2), 
and place FCoE ports into a supported VLAN.
When CEE is turned on and the regular FCoE configuration is complete, FCoE 
traffic will be automatically assigned to PFC priority 3, and be initially allocated 
50% of port bandwidth via ETS.
RS G8264(config)# no fcoe fips automatic­vlan
RS G8264(config)# cee enable
Note: Turning CEE on will automatically change some 802.1p QoS and 802.3x 
standard flow control settings and menus (see "Turning CEE On or Off" on 
page
368).
RS G8264(config)# fcoe fips enable
RS G8264(config)# system server­ports port 17­24
RS G8264(config)# interface port 17­24,46
RS G8264(config­if)# switchport mode trunk
RS G8264(config­if)# exit
21, "FCoE and CEE"). Similar to the iSCSI 
366) via port 46. Ports 17‐24 
375):
(Select FCoE ports)
(Enable VLAN tagging)
(Exit port configuration mode)
Chapter 19: Virtual NICs
337

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents