Sflow Example Configuration - Lenovo RackSwitch G8264 Application Manual

For lenovo enterprise network operating system 8.4
Hide thumbs Also See for RackSwitch G8264:
Table of Contents

Advertisement

sFlow Example Configuration

1. Specify the location of the sFlow analyzer (the server and optional port to which 
2. On a per‐port basis, define the statistics polling rate:
3. On a per‐port basis, define the data sampling rate:
4. Save the configuration.
696
G8264 Application Guide for ENOS 8.4
the sFlow information will be sent):
RS G8264(config)# sflow server <IPv4 address>
RS G8264(config)# sflow port <service port>
RS G8264(config)# sflow enable
By default, the switch uses established sFlow service port 6343.
To disable sFlow features across all ports, use the no sflow enable command.
RS G8264(config)# interface port <port>
RS G8264(config­if)# sflow polling <polling rate>
Specify a polling rate between 5 and 60 seconds, or 0 to disable. By default, polling 
is 0 (disabled) for each port.
RS G8264(config­if)# sflow sampling <sampling rate>
Specify a sampling rate between 256 and 65536 packets, or 0 to disable. By default, 
the sampling rate is 0 (disabled) for each port.
(sFlow server address)
(Set the optional service port)
(Enable sFlow features)
(Statistics polling rate)
(Data sampling rate)