Lenovo RackSwitch G8264 Application Manual page 220

For lenovo enterprise network operating system 8.4
Hide thumbs Also See for RackSwitch G8264:
Table of Contents

Advertisement

10. Configure the VLAN for VLAG 2. 
11. Map the VLAN to an MSTI. 
12. Disable VLAG. 
13. Add VLAG ports to the VLAN. 
14. Enable VLAG. 
15. Enable ISL ports and VLAG ports: 
16. Place the VLAG 2 ports in a port trunk group:
17. Assign the trunk to the VLAG:
220
G8264 Application Guide for ENOS 8.4
RS G8264(config)# vlan 100
RS G8264(config­vlan)# exit
Note: The VLAN is automatically mapped to CIST.
RS G8264(config)# spanning­tree mst 1 vlan 100
Note: At this point, traffic may be momentarily disrupted due to STP 
recalculation.
RS G8264(config)# no vlag enable
Note: At this point, traffic may be momentarily disrupted due to STP 
recalculation.
RS G8264(config)# interface port 1­2,8
RS G8264(config­if)# switchport mode trunk
RS G8264(config­if)# switchport trunk allowed vlan 100
RS G8264(config­if)# exit
RS G8264(config)# vlag enable
Note: At this point, traffic may be momentarily disrupted due to STP 
recalculation.
On VLAG Peer 1:
RS G8264(config)# interface port 1­2,8
RS G8264(config­if)# no shutdown
On VLAG Peer2:
RS G8264(config)# interface port 8
RS G8264(config­if)# lacp mode active
RS G8264(config­if)# lacp key 1000
RS G8264(config­if)# exit
RS G8264(config)# vlag adminkey 1000 enable

Hide quick links: