Binding Members To The Stack; Assigning A Stack Backup Switch - Lenovo RackSwitch G8264 Application Manual

For lenovo enterprise network operating system 8.4
Hide thumbs Also See for RackSwitch G8264:
Table of Contents

Advertisement

Binding Members to the Stack

Assigning a Stack Backup Switch

308
G8264 Application Guide for ENOS 8.4
RS G8264(config)# show stack attached­switches
Attached Switches in Stack: 
­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­
asnum           MAC          csnum  State
­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­
 A1     74:99:75:d1:fc:00    C1     IN_STACK           
 A2     74:99:75:d0:99:00    C2     IN_STACK           
 A3     74:99:75:d1:e9:00    C3     IN_STACK           
RS G8264(config)#
You can bind Member switches to a stack csnum using either their asnum or MAC 
address :
RS G8264(config)# stack switch­number <csnum> mac <MAC address>
‐or‐
RS G8264(config)# stack switch­number <csnum> bind <asnum>
To remove a Member switch, execute the following command:
RS G8264(config)# no stack switch­number <csnum>
To bind all units of a stack, use the command:
RS G8264(config)# stack bind
The stack bind command automatically assigns switch numbers to all attached 
switches in the stack that do not yet have a number assigned.
To define a Member switch as a Backup (optional) which will assume the Master 
role if the Master switch fails, execute the following command:
RS G8264(config)# stack backup <csnum>

Hide quick links: