7. Set VSI database information. 
8. Enable LLDP. 
398
G8264 Application Guide for ENOS 8.4
RS G8264(config)# virt evb vsidb 1
RS G8264(conf­vsidb)# protocol {http|https} (Select VSI database protocol; default is 
HTTP)
RS G8264(conf­vsidb)# host 172.31.37.187 [data­port|mgt­port]
RS G8264(conf­vsidb)# port 80 
RS G8264(conf­vsidb)# filepath "vsidb" (Set VSI database document path)
RS G8264(conf­vsidb)# filename "all.xml"(Set VSI database file name)
RS G8264(conf­vsidb)# update­interval 30(Set update interval in seconds) 
RS G8264(conf­vsidb)# exit
Note: When you connect to an SNSC VSIDB, the port/docpath configuration is as 
follows:
HTTP:
Port: 40080
Docpath: snsc/rest/vsitypes
HTTPS:
Port: 40443
Docpath: snsc/rest/vsitypes
When you connect to a 5000v VSIDB, the port/docpath configuration is as follows:
Port: 80
Docpath: vsitypes
RS G8264(config)# lldp enable
(Set VSI database Manager IP)
(Set VSI database Manager port)
(Turn on LLDP)