Chapter 3. Configuring the CN4093

© Copyright Lenovo 2017
The switch has an internal Ethernet path to the Chassis Management Module 
(CMM), the external Ethernet data ports, an external management port, and a 
serial console port. The switch supports two remote‐access modes for management 
through Ethernet connections. You can select the mode that is best suited for your 
Lenovo Flex System environment.
Default mode: The default mode uses the internal path to the CMM only. In this 
mode, the remote‐access link to the management console must be attached to the 
Ethernet connector on the CMM. The Internet Protocol (IP) addresses and 
Simple Network Management Protocol (SNMP) parameters of the switch can be 
automatically assigned by the Lenovo Director Flex System Deployment wizard 
(when available), or you must assign them through the Lenovo Flex System 
Management and Configuration program. This mode enables you to provide a 
secure LAN for management of the Lenovo Flex Systems subsystems that is 
separate from the data network. See "Establishing an Interface Through the 
CMM" on page
39 for more information.
External management mode: External management mode allows for the use of 
alternate management entities to control and configure the switch. You must 
enable external management in order to manage the switch using the dedicated 
external management port (EXTM) or any of the external data ports 
(EXT1‐EXT22, in‐band switch management). This mode can be used instead of 
or in addition to access through the CMM. This mode can be enabled only 
through the CMM configuration interface. When this mode is enabled, the 
external ports support both management and data traffic.
This mode enables the use of additional switch IP addresses on different IP 
subnets than the CMMs. This is useful when the switches are to be managed and 
controlled as part of the overall network infrastructure, while secure 
management of other Lenovo Flex System subsystems is maintained through 
the CMM. See "Enabling Management Through Data Ports" on page
additional instructions about configuring the switch for this mode of operation.
The RS‐232 console port provides an alternative path to manage and configure the 
switch for local access.
Important:
Before you configure the switch, make sure that the CMM is correctly 
configured. For more information about configuring the CMM, see the 
following documents:
– Lenovo Flex System Chassis Management Module Installation Guide
– Lenovo Flex System Chassis Management Module User's Guide
The initial default IP address assigned to the switch by the CMM is 
192.168.70.120, 192.168.70.121, 192.168.70.122, or 192.168.70.123 depending on 
the bay where the switch is installed.
If you change the IP address of the switch and restart the Lenovo Flex System 
chassis, the switch maintains this new IP address as its default value.
The CMM and the switch can communicate with each other only if they are on 
the same IP subnet.