Configuring Pvlan - Lenovo ThinkSystem NE2552E Application Manual

Flex switch lenovo enterprise network operating system 8.4
Hide thumbs Also See for ThinkSystem NE2552E:
Table of Contents

Advertisement

Configuring PVLAN

1. Configure VLAN tagging/trunk mode for ports.
2. Create a VLAN and define the protocol type(s) supported by the VLAN.
3. Configure the priority value for the protocol.
4. Add member ports for this PVLAN.
5. Enable the PVLAN.
6. Verify PVLAN operation.      
150
NE2552E Application Guide for ENOS 8.4
Follow this procedure to configure a Protocol‐based VLAN (PVLAN).
NE2552E(config)# interface port ext1,ext2
NE2552E(config-if)# switchport mode trunk
NE2552E(config-if)# exit
NE2552E(config)# vlan 2
NE2552E(config-vlan)# protocol-vlan 1 frame-type ether2 0800
NE2552E(config-vlan)# protocol-vlan 1 priority 2
NE2552E(config-vlan)# protocol-vlan 1 member ext1,ext2
Note: If VLAN tagging is turned on and the port being added to the VLAN has a 
different default VLAN (PVID/Native VLAN), you will be asked to confirm 
changing the PVID to the current VLAN.
NE2552E(config-vlan)# protocol-vlan 1 enable
NE2552E(config-vlan)# exit
NE2552E(config)# show vlan
VLAN
----
--------------------------------
-------------------------
1
Default VLAN
EXT9/1-EXT12/4
10
VLAN 10
20
VLAN 20
40
VLAN 40
60
VLAN 60
80
VLAN 80
4095
Mgmt VLAN
Name
Status MGT
------ ---
ena
ena
ena
ena
ena
ena
ena
Ports
dis
INTA2-INTB14
dis
EXT5-EXT12/4
dis
EXT3 EXT4
dis
empty
dis
EXT1
dis
INTA1 EXT1 EXT2
EXT5-EXT12/4
ena
EXTM MGT1

Hide quick links:

Advertisement

Table of Contents
loading