Software Upgrade; Disconnecting And Reconnecting Ha - AudioCodes Mediant 800 User Manual

Gateways & session border controllers
Hide thumbs Also See for Mediant 800:
Table of Contents

Advertisement

CHAPTER 42    HA Maintenance
Toolbar: Click the Actions button, and then from the drop-down menu, choose
Switchover.
Navigation tree: Setup menu > Administration tab > Maintenance folder > High
Availability Maintenance.
2.
Click Reset; a confirmation box appears requesting you to confirm.
3.
Click OK.

Software Upgrade

You can perform the following types of software upgrades on the HA system:
Software Upgrade with Device Reset: Both active and redundant devices burn and reboot
with the new software version. This method is quick and simple, but it disrupts traffic (i.e.,
traffic affecting).
Hitless Software Upgrade: This method maintains service (i.e., not traffic affecting).
For more information, see

Disconnecting and Reconnecting HA

You can disconnect the two devices in the HA system and return them to standalone devices.
To disconnect HA:
On the active device, enter the following CLI command:
# debug ha disconnect-system < new OAMP address of redundant device >
You can later restore the HA system, by following the below procedure.
To restore the HA system:
1.
On the previously redundant device, configure the HA Maintenance interface address of the
active device in the 'HA Remote Address' field, or through CLI:
(config-network)# high-availability
(ha)# remote-address < HA Maintenance address >
Software
Upgrade.
The new OAMP address of the redundant device must be different to the active
device.
The HA Maintenance network interface (in the IP Interfaces table) on the redundant
device is unaffected by the command.
All Media + Control network interfaces (in the IP Interfaces table) are deleted on
the redundant device.
The 'HA Remote Address' (HARemoteAddr) field value, which specifies the HA
Maintenance address of the active device, is deleted on the redundant device.
The command causes the redundant device to reset.
Mediant 800 Gateway & E-SBC | User's Manual
- 898 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-sbc

Table of Contents