AudioCodes Mediant 800 User Manual page 1095

Gateways & session border controllers
Hide thumbs Also See for Mediant 800:
Table of Contents

Advertisement

CHAPTER 61    Reporting Information to External Party
Field
Local Output
Octets
[607]
Local Output
Packets
[605]
Local
Packet Loss
[608]
Local R
Factor
[625]
Local Round
Trip Delay
Displays the local output octets (bytes).
Note:
The field is optional and can be included in the CDR using the Gateway
CDR Format and SBC CDR Format tables.
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The default field title is empty for RADIUS (ACCT_OUTPUT_ OCTETS
standard ID 43).
The maximum number of characters for Syslog tabular alignment is 10.
Displays the number of packets sent by the device. The field is an integer from
0 to 0XFFFFFFFF.
Note:
The field is included in the default CDR.
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The default field title is "OutPackets" for Syslog and Local Storage, and
empty for RADIUS (ACCT_OUTPUT_PACKETS standard ID 48).
The maximum number of characters for Syslog tabular alignment is 10.
Displays the number of packets lost of the entire stream. The field is an integer
from 0 to 0xFFFFFFFF (-1 if information is unavailable).
Note:
The field is included in the default CDR.
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The default field title is "PackLoss" for Gateway Syslog and Local Storage,
and "LocalPackLoss" for SBC Syslog.
The maximum number of characters for Syslog tabular alignment is 10.
Displays the local R-factor conversation quality. The field is an integer from 0
to 120 (127 if information is unavailable).
Note:
The field is included in the default CDR.
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The default field title is "LocalRFactor".
If the RTCP XR feature is unavailable (not licensed or disabled), this R-
factor VoIP metric is not provided. Instead, the device sends the CDR field
with the value 127, meaning that information is unavailable.
The maximum number of characters for Syslog tabular alignment is 12.
Displays the average round-trip delay time of the entire RTP stream. The field
is an integer from 0 to 10000 ms (-1 if information is unavailable).
- 1055 -
Mediant 800 Gateway & E-SBC | User's Manual
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-sbc

Table of Contents