CHAPTER 23    Digital PSTN
'MAX Incoming Address Digits'
[CasStateMachineMaxNumOfIncomingAddress
Digits]
'MAX Incoming ANI Digits'
[CasStateMachineMaxNumOfIncomingANIDigit
s]
'Collect ANI'
[CasStateMachineCollectANI]
'Digit Signaling System'
[CasStateMachineDigitSignalingSystem]

Configuring Digital Gateway Parameters

The Digital Gateway Parameters page allows you to configure miscellaneous digital parameters.
For a description of these parameters, see
To configure the digital gateway parameters:
1.
Open the Digital Gateway Settings page (Setup menu > Signaling & Media tab > Gateway
folder > Digital Gateway > Digital Gateway Settings).
Parameter
Configuration Parameters
- 577 -
Mediant 800 Gateway & E-SBC | User's Manual
Description
Defines the limitation for the maximum
address digits that need to be collected.
After reaching this number of digits, the
collection of address digits is stopped.
The value must be an integer. The default
is -1 (use value from CAS state machine).
Defines the limitation for the maximum
ANI digits that need to be collected. After
reaching this number of digits, the
collection of ANI digits is stopped.
The value must be an integer. The default
is -1 (use value from CAS state machine).
In some cases, when the state machine
handles the ANI collection (not related to
MFCR2), you can control the state
machine to collect ANI or discard ANI.
[0] No = Don't collect ANI.
[1] Yes = Collect ANI.
[-1] Default = Default value - use value
from CAS state machine.
Defines which Signaling System to use in
both directions (detection\generation).
[0] DTMF = Uses DTMF signaling.
[1] MF = (Default) Uses MF signaling.
[-1] Default = Default value - use value
from CAS state machine.