Ds3 Los Alarm; Software Upgrade Alarm - AudioCodes Mediant 3000 TP-6310 Performance Monitoring And Alarm Manual

Table of Contents

Advertisement

Performance Monitoring and Alarms
3.4.51

DS3 LOS Alarm

This alarm applies only to Mediant 3000 TP-6310.
Description
SNMP Alarm
SNMP OID
Alarm Title
Alarm Source
Alarm Type
Probable Cause
Severity
Additional Info
Corrective Action
3.4.52

Software Upgrade Alarm

Description
This alarm is generated when the Software upgrade failure occurs.
SNMP
acSWUpgradeAlarm
Alarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.70
Alarm Title
Software Upgrade alarm
Alarms
System#0
Source
Alarm Type
processingErrorAlarm
Probable
softwareProgramError
Cause
Alarm
Severity
Major
Raised upon software
(default)
upgrade errors
Version 7.0
DS3 LOS Alarm
This alarm is issued when the LOF condition is present on the DS3
Interface #m.
acDS3LOSAlarm
1.3.6.1.4.1.5003.9.10.1.21.2.0.69
DS3 LOS Alarm
Interfaces#0/DS3#<m>
communicationsAlarm
lossOfFrame
Critical / Cleared
Check the cable connections or cable length
Software Upgrade Alarm
Condition
SW upgrade
error: Firmware
burning failed.
Startup system
from Bootp/tftp.
<text>
Start up the system from BootP/TFTP.
141
Performance Monitoring and Alarms
Corrective Action
3. Alarms