CHAPTER 62    Syslog and Debug Recording
The following procedure describes how to configure Log Filter rules through the Web interface. You
can also configure it through ini file [LoggingFilters] or CLI (configure troubleshoot >
logging logging-filters).
To configure a Log Filter rule:
1.
Open the Logging Filters table (Troubleshoot menu > Troubleshoot tab > Logging folder >
Logging Filters).
2.
Click New; the following dialog box appears:
3.
Configure a Log Filtering rule according to the parameters described in the table below.
4.
Click Apply.
Table 62-1: Logging Filters Table Parameter Descriptions
Parameter
'Index'
[LoggingFilters_Index]
'Filter Type'
filter-type
[LoggingFilters_
FilterType]
If you want to configure a Log Filter rule that logs Syslog messages to a Syslog
server (i.e., not to a Debug Recording server), you must enable Syslog
functionality, using the 'Enable Syslog' (EnableSyslog) parameter (see
Syslog). Enabling Syslog functionality is not required for rules that include Syslog
messages in the debug recording sent to the Debug Recording server.
To configure the Syslog server's address, see
Address. To configure additional, global Syslog settings, see
To configure the Debug Recording server's address, see
Recording Server
Address.
To configure additional, global CDR settings such as at what stage of the call the
CDR is generated (e.g., start and end of call), see
Defines an index number for the new table row.
Note: Each row must be configured with a unique index.
Defines the filter type criteria.
[1] Any= (Default) Debug recording is done for all calls.
[2] Trunk ID = Filters log by Trunk ID.
Note: Applicable only to the Gateway application.
Mediant 800 Gateway & E-SBC | User's Manual
Configuring the Syslog Server
Configuring CDR
Description
- 1097 -
Enabling
Configuring
Syslog.
Configuring the Debug
Reporting.