Configuring Internal Clock As Clock Source - AudioCodes Mediant 800 User Manual

Gateways & session border controllers
Hide thumbs Also See for Mediant 800:
Table of Contents

Advertisement

CHAPTER 23    Digital PSTN
a.
From the 'TDM Bus Clock Source' drop-down list (TDMBusClockSource), select Network
to recover the clock from the line interface.
b.
In the 'TDM Bus Local Reference' field (TDMBusLocalReference), enter the trunk from
which the clock is derived.
c.
Enable automatic switchover to the next available "slave" trunk if the device detects that
the local-reference trunk is no longer capable of supplying the clock to the system:
i.
ii.
iii.
2.
(E1/T1 Trunks Only) Configure the PSTN trunk to recover/derive clock from/to the remote side
of the PSTN trunk (i.e. clock slave or clock master): In the Trunk Settings page, configure the
'Clock Master' parameter (ClockMaster) to one of the following:
Recovered - to recover clock (i.e. slave)
Generated - to transmit clock (i.e. master)

Configuring Internal Clock as Clock Source

You can configure the device to use its internal clock source. The internal clock source is a stratum
4E- compliant clock source. When the device has no line interfaces, the device should be
configured in this mode.
To configure internal clock as clock source:
1.
Set the clock source to be from the device's internal oscillator. In the TDM Bus Settings page,
set the 'TDM Bus Clock Source' parameter (TDMBusClockSource) to Internal.
2.
(E1/T1 Trunks Only) Set the line to drive the clock on all trunks: In the Trunk Settings page, set
the 'Clock Master' parameter (ClockMaster) to Generated (for all trunks).
The E1/T1 trunk should recover the clock from the remote side (see below
description of the 'Clock Master' parameter).
The BRI trunk should be configured as an ISDN user-side.
From the 'TDM Bus PSTN Auto FallBack Clock' drop-down list
(TDMBusPSTNAutoClockEnable), select Enable.
From the 'TDM Bus PSTN Auto Clock Reverting' drop-down list
(TDMBusPSTNAutoClockRevertingEnable), select Enable to enable the device to
switch back to a previous trunk that returns to service if it has higher switchover
priority.
In the Trunk Settings page (see
level of the trunk for taking over as a local-reference trunk, using the 'Auto Clock
Trunk Priority' parameter (AutoClockTrunkPriority). A value of 100 means that it never
uses the trunk as local reference.
Mediant 800 Gateway & E-SBC | User's Manual
Configuring Trunk
Settings), configure the priority
- 574 -