CHAPTER 72    Configuration Parameters Reference
'ReRegister On Connection Failure'
configure voip > sip-
definition proxy-and-
registration > reg-on-
conn-failure
[ReRegisterOnConnectionFailure]
'Gateway Registration Name'
configure voip > sip-
definition proxy-and-
registration > gw-
registration-name
[GWRegistrationName]
'Registration Mode'
configure voip > sip-
definition proxy-and-
registration >
authentication-mode
[AuthenticationMode]
Parameter
Mediant 800 Gateway & E-SBC | User's Manual
Description
The device terminates a call due to the
expiration of RFC 3261 Timer B or due to the
receipt of a 408 (Request Timeout) response
and the device has not received any provisional
response for the call (indicative of an outbound
proxy server failure).
The device terminates a call due to the receipt
of a 408 (Request Timeout) response and the
only provisional response the device has
received for the call is the 100 Trying
provisional response (indicative of a home
proxy server failure).
Note: The parameter is applicable only to the Gateway
application.
Enables the device to perform SIP re-registration upon
TCP/TLS connection failure.
[0] Disable (default)
[1] Enable
Defines the user name that is used in the From and To
headers in SIP REGISTER messages. If no value is
specified (default) for the parameter, the UserName
parameter is used instead.
Note:
The parameter is applicable only to the Gateway
application.
The parameter is applicable only for single
registration per device (i.e., AuthenticationMode is
set to 1). When the device registers each channel
separately (i.e., AuthenticationMode is set to 0), the
user name is set to the channel's phone number.
Determines the device's registration and authentication
method.
[0] Per Endpoint = Registration and authentication
is performed separately for each endpoint or B-
channel. This is typically used for FXS interfaces,
where each endpoint registers (and authenticates)
separately with its user name and password.
[1] Per Gateway = (Default) Single registration and
authentication for the entire device. This is typically
used for FXO interfaces and digital interfaces.
[3] Per FXS = Registration and authentication for
FXS endpoints.
Note: The parameter is applicable only to the Gateway
application.