Field
Remote R
Factor
[626]
Remote
Round Trip
Delay
[617]
Remote
RTP IP
[622]
Remote
RTP Port
[623]
Remote SIP
User Agent
[818]
Displays the remote R-factor conversation quality. The field is an integer from 0
to 120 (127 if information is unavailable).
Note:
The field is included in the default CDR.
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The default field title is "RemoteRFactor".
If the RTCP XR feature is unavailable (not licensed or disabled), this R-
factor VoIP metric is not provided. Instead, the device sends the CDR field
with the value 127, meaning that information is unavailable.
The maximum number of characters for Syslog tabular alignment is 13.
Displays the average round-trip delay time of the remote RTP stream. The field
is an integer from 0 to 10000 ms (-1 if information is unavailable).
Note:
The field is optional and can be included in the CDR using the SBC CDR
Format tables..
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The maximum number of characters for Syslog tabular alignment is 9.
Displays the remote RTP IP address.
Note:
The field is included in the default CDR.
The field is applicable only to "CALL_END", "CALL CONNECT", "MEDIA_
START", "MEDIA_UPDATE", and "MEDIA_END" CDR Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The default field title is "RtpIp" for Syslog Signaling and Local Storage,
"RemoteRtpIp" for Syslog Media, and "h323-remote-address=" for
RADIUS.
The maximum number of characters for Syslog tabular alignment is 20.
Displays the remote RTP port. This field is an integer from 0 to 0xFFFF.
Note:
The field is included in the default CDR.
The field is applicable only to "CALL_END", "CALL_CONNECT",
"MEDIA_START", "MEDIA_UPDATE", and "MEDIA_END" CDR Report
Types.
The field is applicable only to SBC media and Gateway CDRs.
The default field title is ""Port" for Syslog Signaling and "RemoteRtpPort"
for Syslog Media.
The maximum number of characters for Syslog tabular alignment is 5.
Displays the remote SIP User-Agent header value.