CHAPTER 72    Configuration Parameters Reference
Parameter
Regional Clock and Daylight Saving Time Parameters
'UTC Offset'
configure system >
clock > utc-offset
[NTPServerUTCOffset]
'Daylight Saving Time'
configure system >
clock > summer-time >
summer-time
[DayLightSavingTimeEnable]
'Start Time / Day of Month
Start'
configure system >
clock > summer-time >
start
[DayLightSavingTimeStart]
'End Time / Day of Month End'
configure system >
clock > summer-time >
end
[DayLightSavingTimeEnd]
'Offset'
configure system >
clock > summer-time >
offset
[DayLightSavingTimeOffset]
Mediant 800 Gateway & E-SBC | User's Manual
Defines the Universal Time Coordinate (UTC) offset (in
seconds) from the local time.
The valid range is -86400 seconds (i.e., -24 hours) to +86400
seconds (i.e., +24 hours). The default is 0.
Note: The offset setting is applied only on the hour. For
example, if you configure the parameter at 15:42, the device
applies the setting only at 16:00.
Enables daylight saving time (DST).
[0] Disable (default)
[1] Enable
Defines the date and time when DST begins. This value can
be configured using any of the following formats:
Day of year - mm:dd:hh:mm, where:
mm denotes month
dd denotes date of the month
hh denotes hour
mm denotes minutes
For example, "05:01:08:00" denotes daylight saving start-
ing from May 1 at 8 A.M.
Day of month - mm:day/wk:hh:mm, where:
mm denotes month (e.g., 04)
day denotes day of week (e.g., FRI)
wk denotes week of the month (e.g., 03)
hh denotes hour (e.g., 23)
mm denotes minutes (e.g., 10)
For example, "04:FRI/03:23:00" denotes Friday, the third
week of April, at 11 P.M. The week field can be 1-5,
where 5 denotes the last occurrence of the specified day
in the specified month. For example, "04:FRI/05:23:00"
denotes the last Friday of April, at 11 P.M.
Defines the date and time when DST ends. For a description
of the format of this value, see the DayLightSavingTimeStart
parameter.
Defines the DST offset (in minutes).
The valid range is 0 to 120. The default is 60.
Note: The offset setting is applied only on the hour. For
example, if you configure the parameter at 15:42, the device
applies the setting only at 16:00.
- 1185 -