Output
Measured duration, in minutes, when the temperature is less than the minimum
CUMULATIVE
temperature or duration of the current defrost cycle.
TIME:
Parameters
CUMULATIVE OPERATING TIME: Time T, in minutes, at the end of which the function
triggers defrosting (1 to 32767).
DEFROST CYCLE: Duration of defrosting in minutes (1 to 32767).
MAXIMUM TEMPERATURE: Temperature in °C above which defrosting is stopped
(10°C ... 20°C).
MINIMUM TEMPERATURE: Temperature in °C below which the time T is measured
(-10°C ... 0°C).

5.5.52 Comparison of 2 values

Fashion:
Short Description
The COMPARE function is used to compare two analog values.
209