CDM-750 Advanced High-Speed Trunking Modem
Appendix D
To continue, consider this example: 
 
Satellite & Transponder
Earth Station 1
Earth Station 2
Data Rate
 
Whereas  the  original  link  used  8PSK  TPC  3/4,  the  CnC  link  used  DVB‐S2  8PSK  3/4.  The  savings 
summary  is  as  follows  –  using  CnC  and  DVB‐S2  reduced  the  leased  bandwidth  by  almost  50% 
and HPA power by almost 60%: 
 
Item
Data Rate (kbps)
Modulation
FEC
Occupied BW (MHZ)
Power Eq. BW (MHz)
Leased BW (MHz)
Hub HPA (W)
Remote HPA (W)
 
Note: 1 dB HPA BO for QPSK, 2 dB HPA BO for 8PSK, 1 dB Feed Loss. 
 
IS-901 @ 342º W, 22/22 (EH/EH)
Africa – 9.1 m
Africa – 4.5 m
20.48 Mbps / 20.48 Mbps
Original Link
Hub to
Remote
Total
Remote
To Hub
20.48
20.48
8PSK
8PSK
TPC 3/4
TPC 3/4
13.1
13.1
26.2
10.3
4.9
15.2
-
-
26.2
44
112
D–15
With Carrier-in-Carrier
Hub to
Remote to
Remote
Hub
-
20.48
20.48
-
8PSK
8PSK
-
S2 3/4
S2 3/4
13.2
13.2
6.4
2.0
-
-
27
47
Revision 2
MN-CDM750
Savings
Total
-
-
-
13.2
8.4
13.2
49.6%
38.3%
58.3%