CDM-750 Advanced High-Speed Trunking Modem
Serial-based Remote Product Management
Command
Parameter
Number of
(Instruction
Type
Arguments
& Qualifier)
PIIC Rx Buffer
RBS=
6 bytes
Size
Re Center
RCB=
None
Buffer
Description of Arguments
Command or Query.
Set or return Rx Buffer Size (in ms), in the form sxxx.x where:
s = Interface Slot, where:
1 = Slot 1
2 = Slot 2
xxx.x = Rx Buffer Size, in 0.5 ms steps, from 2.0 to 75.0 ms
Example: RBS=1032.5 (selects 32.5 ms for Slot 1)
Command only.
Force the software to recenter the receive buffer in the form x, where:
s = Interface Slot, where:
1 = Slot 1
2 = Slot 2
Example: RCB=2 (re-centers the buffer on the Slot 2 interface card)
7–29
Revision 2
MN-CDM750
Query
Response to
(Instruction &
Response to Query
Command
Qualifier)
RBS =
RBS?s
RBS =
RBS?
(see Description of
RBS *
Arguments)
RBS #
RCBs=
N/A
N/A
RCB?
RCB#
RCB*
Need help?
Do you have a question about the CDM-750 and is the answer not in the manual?
Questions and answers