Redundancy Control - Comtech EF Data CDM-750 Installation And Operation Manual

Advanced high-speed trunking modem
Hide thumbs Also See for CDM-750:
Table of Contents

Advertisement

CDM-750 Advanced High-Speed Trunking Modem
Serial-based Remote Product Management

7.5.12 Redundancy Control

Command
Parameter
Number of
(Instruction
Type
Arguments
& Qualifier)
1:1
ASW
1 byte, value
Operational
of 0 or 1
Mode
1:1 Force Unit
FSW=
1
Offline
1:1
N/A
0
Redundancy
Unit online or
offline
1:N
R1N=
1 byte, value
Redundancy
of 0 or 1
Enable
1:1
N/A
1 byte, value
Redundancy
of 0 or 1
Switch
Available
 
Description of Arguments
Command or Query.
Set or return 1:1 operational mode in the form x, where:
0 = Unit is in Manual mode
1 = Unit is in Auto mode.
NOTE: In Manual Mode, all fault relays are forced to the non-faulted condition. This allows an online unit to be
configured without undesired switchover to a backup unit (Changing Rx frequency would normally cause the
online unit to unlock and a switchover to the backup modem would occur).
Command only.
There are no parameters associated with this command. In a 1:1 switch environment, this command forces an
online unit offline. If the unit is offline, then no action is taken.
Notes:
1. The 1:1 redundancy system must be installed!
2. Both online and offline units must be in Manual Mode for this command to function.
3. If the 1:1 redundancy system is not installed, then the command will return FSW?
4. If the unit is offline, then the command will return FSW?
Example: FSW=
Query only.
Return 1:1 online/offline status in the form x, where:
0 = Unit is offline
1 = Unit is online
Example: RED?1 (indicating the unit is online)
Command or Query.
Sets or returns 1:N operational mode in the form x, where:
0 = Unit is not enabled for 1:N switch operation.
1 = Unit is enabled for 1:N switch operation.
Example: R1N=1 (indicating the unit is enabled for 1:N)
Query only.
Returns 1:1 switch status in the form x, where:
0 = Unit is not connected to a 1:1 switch
1 = Unit is connected to a 1:1 switch
Example: R11?0 (indicating the unit is not connected to a 1:1 switch)
7–42
Revision 2
MN-CDM750
Query
Response to
(Instruction &
Response to Query
Command
Qualifier)
ASW=
ASW?
ASW=x
ASW?
(see description
ASW *
of arguments)
ASW #
FSW=
FSW?
FSW=
FSW?
N/A
RED?
RED=x
R1N=
R1N?
R1N=x
R1N?
(see description
R1N *
of arguments)
R1N #
N/A
R11?
R11=x