Ac Operation - Replacing Fuses; Figure 3-9. Replacing Cdm-750 Ac Fuses - Comtech EF Data CDM-750 Installation And Operation Manual

Advanced high-speed trunking modem
Hide thumbs Also See for CDM-750:
Table of Contents

Advertisement

CDM-750 Advanced High-Speed Trunking Modem
Rear Panel Connections
3.3.2.2
AC Operation – Replacing Fuses
For AC operation the CDM‐750 uses two common 5mm x 20mm Slow‐blow fuses – one each for 
line and neutral connections. The fuses are contained within a fuse holder that is press‐fit into 
the body of the IEC power module (located on the rear panel, Figure 3‐9). 
 
 
 
 
 
 
 
 
 
 
To replace the fuse(s), follow these steps (Figure 3‐9): 
 
DISCONNECT THE POWER SUPPLY BEFORE PROCEEDING! 
 
First, unseat the fuse holder from the IEC power module. 
 
o Use the slot to pry the holder outward from the IEC power module.  
 
o Pull the holder straight out, and then swing the holder away from the module.  
 
Then, remove and replace the T4A (4 Amp) fuses as needed. 
 
 
FOR  CONTINUED  OPERATOR  SAFETY,  ALWAYS  REPLACE  THE  FUSES  WITH  THE 
CORRECT TYPE AND RATING. 
 
Finally, re‐seat the fuse holder in the IEC power module. 

Figure 3-9. Replacing CDM-750 AC Fuses

3–16
Revision 2
MN-CDM750