CDM-750 Advanced High-Speed Trunking Modem
Serial-based Remote Product Management
2. USE  OF  THE  SERIAL‐BASED  REMOTE  PRODUCT  MANAGEMENT  INTERFACE  IS  RECOMMENDED  ONLY  FOR  ADVANCED 
USERS. ALL OTHER USERS ARE STRONGLY ENCOURAGED TO USE THE CDM‐750 FRONT PANEL OR CDM‐750 WEB SERVER 
INTERFACE  FOR  MONITOR  AND  CONTROL  (M&C)  OF  THE  CDM‐750.  SEE  CHAPTER  5.  FRONT  PANEL  OPERATION  OR 
CHAPTER 6. ETHERNET‐BASED REMOTE PRODUCT MANAGEMENT. 
 
The  CDM‐750  Advanced  High‐Speed  Trunking  Modem  serial  remote  product  management  interface  is  an  electrical  interface  that  is 
either an EIA‐485 multi‐drop bus (for the control of multiple devices) or an EIA‐232 connection (for the control of a single device). The 
interface  transmits  data  in  asynchronous  serial  form,  using  ASCII  characters.  This  data  consists  of  control  and  status  information, 
transmitted in packets of variable length in accordance with the structure and protocol explained later in this chapter. 
7.2
EIA-485
For applications where multiple devices are to be monitored and controlled, a full‐duplex (or 4‐wire plus ground) EIA‐485 is preferred. 
Half‐duplex  (2‐wire  plus  ground)  EIA‐485  is  possible,  but  is  not  preferred.  In  full‐duplex  EIA‐485  communication,  there  are  two 
separate, isolated, independent, differential‐mode twisted pairs, each handling serial data in different directions.  
 
It  is  assumed  that  a  'Controller'  device  (a  PC  or  dumb  terminal)  transmits  data  in  a  broadcast  mode  via  one  of  the  pairs.  Multiple 
'Target' devices are connected to this pair, and all simultaneously receive data from the Controller. The Controller is the only device 
with a line‐driver connected to this pair – the Target devices have only line‐receivers connected. 
 
In  the  other  direction,  on  the  other  pair  each  Target  has  a  tri‐state  line  driver  connected,  and  the  Controller  has  a  line‐receiver 
connected. All the line drivers are held in high‐impedance mode until one (and only one) Target transmits back to the Controller. Each 
Target  has  a  unique  address,  and  each  time  the  Controller  transmits,  the  address  of  the  intended  recipient  Target  is  included  in  a 
framed 'packet' of data. All of the Targets receive the packet, but only one (the intended) will reply. The Target enables its output line 
driver and transmits its return data packet back to the Controller in the other direction, on the physically separate pair. 
 
EIA‐485 (full duplex) summary: 
 
Two differential pairs – one pair for Controller‐to‐Target, one pair for Target‐to‐Controller. 
Controller‐to‐Target pair has one line driver (Controller), and all Targets have line‐receivers. 
Target‐to‐Controller pair has one line receiver (Controller), and all Targets have Tri‐State drivers. 
 
7–2