Comtech EF Data CDM-750 Installation And Operation Manual page 85

Advanced high-speed trunking modem
Hide thumbs Also See for CDM-750:
Table of Contents

Advertisement

CDM-750 Advanced High-Speed Trunking Modem
Front Panel Operation
5. The best practice when entering or leaving MultiStream Mode is to perform the 
following procedures: 
 
A. ENTERING INTO MULTISTREAM MODE 
B. EXITING OUT OF MULTISTREAM MODE 
 
Step 
Task 
Use the     arrow keys to select the CONFIG: Intf menu. 
Select  any  combination  of  GbE  interface  operation  (GBE1  /  J5  |  DATA 
port, GBE2 / J6 |DATA port, or Optical / J7 | OPTICAL port), and ensure 
that  both  interface  slots  (PIIC1  and  PIIC2)  are  either  not  installed 
(NONE) or not active (Off). 
Configure the modem settings for MultiStream Mode operation: 
Select the Tx parameters for the carrier that will act as the aggregate 
carrier of all interface types to be transmitted.  
Choose the proper ModCods, Pilots, Symbol Rate, etc. to ensure that 
your total Tx uplink can accommodate all of the interface types that 
you intend to multiplex together. 
Once you have completed Step 2, you  will know your  total Tx  data rate 
that  the  modem  can  accommodate,  This  Tx  data  rate  must  be  able  to 
support the aggregate interface type services you plan to transmit. 
Return to the CONFIG: Intf menu to enable one or both of the PIIC data 
interface traffic types. 
If the PIIC interface type(s) requires more Tx data rate capacity than what 
had been configured for the modem, the CONFIG: Intf type selection for 
the PIIC interface(s) will reject the PIIC settings executed in Step 5. Return 
to Step 1 to make the necessary corrections. 
 
 
Step 
Task 
Use the     arrow keys to select the CONFIG: Intf menu. 
FIRST, disable both interface slots (PIIC1 and PIIC2), ensuring  that both 
are either not active (Off), or not installed (NONE). 
NEXT,  disable  all  GbE  interfaces,  ensuring  that  all  three  are  either  not 
active  (Off)  or,  as  it  applies  to  the  J7  |  OPTICAL  port  SFP  module,  not 
installed (NONE). 
Enable a single PIIC interface, or any combination of the GbE interfaces. 
Use  the      arrow  keys  to  select  the  CONFIG:  Tx  →  Data  →  Tx  Data 
Rate  menu.  There,  confirm  that  the  Tx  Data  Rate  MIN_DR  variable  is 
displayed as 000000.000. 
5–9
Revision 2
MN-CDM750