DNC Plant/DNC Cell (FBDN1)
12 Auto archiving

12.2.5 Start parameters for auto archive

The auto archive function has two start parameters.
ONLYCOMP
This parameter determines whether the setting for the machines is to apply for the
archive run, or whether the archive run is to be skipped and just the comparison
carried out.
Without the start parameters, the archive function is carried out depending on how
the machine has been set.
When the "ONLYCOMP" start parameter is set, only the comparison function is
carried out on all the machines for which "Auto Compare" is configured, regardless
of whether the "Auto Archive" function is also configured.
Call:
DNCAArch.exe ONLYCOMP
SHOW_FILESONDNC
This parameter determines whether the NC data found in the DNC system only is
to be displayed in the comparison results.
Without this parameter, this NC data is not displayed in the comparison results
because it is usually of little relevance for the auto archive function.
This NC data is displayed if the start parameter "SHOW_FILESONDNC" is set.
Call:
DNCAArch.exe SHOW_FILESONDNC
DNCAArch.exe ONLYCOMP SHOW_FILESONDNC