05.07
[FTP]
; FTP parameters (only for FTP protocol = 1/2) relevant.
FTP-HOST =DAISY
FTP-User =A99399958D9895928F
FTP-PW =A98CA48E93A092C79EA8A18E8FD59A96A1A696
; Transfer mode (1=ASCII/2=Binary)
FTP-Mode =2
[DCOM]
; DCOM configuration:
DOMAIN =DNC_DOM
USER = John Do
PASSWORD = A98CA48E93A092C79EA8A18E8FD59A96A1A696
[REMOTELOGIN]
REMOTELOGIN=0
[PATHS]
; Path names without final backslash
MMCIniDrive =F:
; Data directory of MCIS DNC for access to the NC data
; The drive specification must be from the DNC IFC viewpoint
; Either connected network drives (1.) can be specified
; or computer and path in UNC notation (2.)
; FTP (3.), the path must be specified in the notation required
required
; by the FTP server
;
;WorkPathDNC =N:
;
;WorkPathDNC =\\DAISY\DNC$\Data
;
;WorkPathDNC =/DNC/Data
WorkPathDNC =\\DAISY\DNC\Data
; DHSTempPath for the temporary storage of files during transfer for
; DHS server and FTP.
Windows
; environment variable %TEMP% is used.
DhsTempPath =
; DriveInternPath for DHS Open
; (Values:
/ 2= Evaluate all headers)
; Caution:
or 2
DriveInternPath =0
; If DriveInternPath =2 and DIPNoWP =1, then the file compiled ;from all
workpieces in the upload directory, is not stored in ;a workpiece, but
directly in the upload directory.
DIPNoWP=1
[FILES]
LogFile =DNC_IFC.log
ErrLogLen =10
[MACHINE]
; Station name in MCIS DNC
MACHINE = PCU50_840D
; Path for upload
; 0= Machine / 1= Group / 2= Main group
DefUpload =0
© Siemens AG 2010 All Rights Reserved
Motion Control Information System DNC (FBDN) - 04/10 Edition
DNC IFC SINUMERIK - Downloading NC Data via a Network (FBDN2)
Login
(1.)
N:
Is connected to DNC\Data on the MCIS DNC server
(2.)
UNC notation
(3.)
Path specification for the FTP server
If DHSTempPath is empty, the content of the
0= Do not evaluate file header / 1= Evaluate first header
If DataTypeChange=Y -> DriveInternPath cannot be set to 1
5 Configuration file
When using
FBDN2/5-35