Siemens Sinumerik 840D sl Function Manual page 203

Motion control information system
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

05.07
[DIALOGFUNCTION]
;---DlgScanLines---: (number of the signifcant lines, beginning with line 1)
DlgScanLines=10
;---Parameters in special ASCII-Character- Words---
;---DlgID---: (Name of the dialogue file)
DlgID=%MPF9999
;---DlgIDSend---: (Name of the answer file (list, error), sent from DNC_NT to
machine)
DlgIDSend=%MPF9998
;---DlgSendEnd---: (Program End for the answer file (list, error), sent from DNC_NT
to machine)
DlgSendEnd=M30
;---DlgSendCmd---: (character which indicades to download a file with releaseID)
DlgSendCmd=(S)
;---DlgSendTcCmd---: (character which indicades to download a file with trialcutID)
DlgSendTcCmd=(ST)
;---DlgReceiveCmd---: ( character which indicades to upload a file from machine to
DNC)
DlgReceiveCmd=(R)
;---DlgSendListCmd---: ( character which indicades to download a filelist of the
machinedirectory in DNC)
DlgSendListCmd=(SL)
;---DlgWpdMark---:
DlgWpdMark=WPD
;if it is impossible to write MPF, SPF, TOA ... you can define a character followed
by a number
;Y001 = MPF, Y002 = SPF, Y003 = TOA ... ordernumber as defined in Databasetable
NCDATATYPE
DlgExchangeCNCType=
;in exchange for * if it is impossible to write *, eg. X999 (only for use with
DlgSendListCmd!)
DlgExchangeWildcard=
;DlgConverter=DNCDlgI.DNCCntrl
DlgConverter=
DlgSubNumber=0
;CutFromName=
;------- The following parameters are directly corresponding to MiniDNC -------------
--------------
;
;MiniDNC
;#####################################
;
[COM]
;
#1210
;
#1211
;
#1401
;
#1402
;
#1403
;
#1501
;
#1502
;
#1503
;
not existent
;
[SEND]
;
#1201
;
#1202
;
not existent
;
not existent
;
#1205
;
#1207
;
#1204
;
#1206
;
#1209
;
#1208
;
not existent
;
#1217
;
#1218
;
#1219
;
#1220
;
not existent
;
not existent
;
#1203
;
not existent
;
#1103
;
#1401
© Siemens AG 2010 All Rights Reserved
Motion Control Information System DNC (FBDN) - 04/10 Edition
(allows to change the shortcut of an workpiece directory)
DNC_NT-2000
[COM] XONChar
[COM] XOFFChar
[COM] ComPort,
[COM] FlowCtrl,
[COM] BaudRate, Parity, ByteSize, StopBits
[COM] ComPort,
[COM] FlowCtrl,
[COM] BaudRate, Parity, ByteSize, StopBits
[COM] binary
[SEND] ProgramStart
[SEND] ProgramEnd
[SEND] CommentStart
[SEND] CommentEnd
[SEND] HeaderChar
[SEND] TrailerChar
[SEND] HeaderSize
[SEND] TrailerSize
[SEND] SpacerChar
[SEND] SpacerSize
[SEND] SkipFirstSpacerMark
[SEND] SpacerMark1
[SEND] SpacerMark2
[SEND] SpacerMark3
[SEND] SpacerMarkInsertAfter1
[SEND] SpacerMarkInsertAfter2
[SEND] SpacerMarkInsertAfter3
[SEND] EOBcode
[SEND] SuppressComment
[SEND] SendTimeout
[SEND] SendBaudRate
DNC Plant/DNC Cell (FBDN1)
or Paramter: [SEND] SendBaudRate
10 Configuration
FBDN1/10-195

Advertisement

Table of Contents
loading

Table of Contents