DNC Plant/DNC Cell (FBDN1)
10 Configuration
Data Stream Interpretation tab page / [RECEIVE] section
The Data Stream Interpretation tab page is defined in the [RECEIVE] section of the
machine configuration file.

Fig. 10-13: Config dialog / Data Stream Interpretation tab page

Note
If the number of significant lines (NCNameLines) > 0, with no separator strings
defined for the workpiece ID or type ID, this is identified as an error in the
machine configuration (red dot on the machine icon).
If the dialog function and data stream interpretation are active, the data stream
interpretation has priority over the dialog function, even if a request program has
been received immediately beforehand.
If the data received does not constitute a request program and does not contain
the IDs (start identifier, workpiece identifier, etc.) for interpreting the data stream,
the data is discarded.
If the data received contains a type that is not known to DNC, the data will be
rejected with an error message. In this case, nothing is saved.