Interpretation mode
Interpretation mode (NCSplit parameter) specifies how the received data can be
split. Three values can be set for this parameter.

Table 10-8: Data stream interpretation: Interpretation mode: NCSplit parameter

Interpretation mode
NCSplit = 0
NCSplit = 1
NCSplit = 2
If third-party controllers (other controllers) are connected, the syntax of the lines
to be interpreted is not clearly specified.
In this case, configuration parameters are used to specify how separators in the
data as well as the NC program file name and type are defined.
Parameter for determining the file name
Table 10-9: Data stream interpretation: Configuration parameters for NC data files for other controllers
(NCSplit=2)
Parameter
Number of Significant
Lines (NCNameLines)
Start Identifier
(NCNameBegin)
Separator Workpiece /
NC Name
(NCNameWPD)
Separator NC Name /
Type (NCNameWPD)
End identifier
(NCNameEnd)
Note
Each individual NC program should always have a name with identifiers (start
identifier, workpiece ID, etc.) so that the data stream can be interpreted. This
helps prevent any confusion.
If this is not possible, the name of the NC program saved beforehand is used,
and a consecutive number is appended (_i (i=1,2,3....) in order to make a
distinction between the programs. The file name (of the entire data stream)
specified by the operator is used for the first NC program.
© Siemens AG 2010 All Rights Reserved
Motion Control Information System DNC (FBDN) - 04/10 Edition
Description
Disabled
SINUMERIK*:
This activates the name assignment in accordance with the
SINUMERIK convention. The parameters for determining the
file name are of no significance. The start-of-program and
end-of-program identifiers must be parameterized.
Other controller:
The parameters for determining the file name as well as the
start-of-program and end-of-program identifiers must be
parameterized.
Type
Description
Integer Number of lines as of the start of the program in which a search is
made for the name string
0 = function deactivated (default)
String
String for identifying the start of the name
String
Separator string between the workpiece and NC program name
String
Separator string between the NC program name and type
String
String for identifying the end of the NC program name
DNC Plant/DNC Cell (FBDN1)