Parameter Descriptions
3.2.5 0-4* LCP Keypad
Enable, disable and password protect individual keys on the
LCP.
0-40 [Hand on] Key on LCP
Option:
Function:
[0]
Disabled
No effect when [Hand on] is pressed. Select
*
[0] Disabled to avoid accidental start of the
drive in Hand on mode.
[1]
Enabled
The LCP switches to Hand on mode directly
*
when [Hand on] is pressed.
[2]
Password
After pressing [Hand on] a password is
required. If 0-40 [Hand on] Key on LCP is in
included in My Personal Menu, define the
password in 0-65 Quick Menu Password.
Otherwise define the password in 0-60 Main
Menu Password.
[3]
Hand Off/On
When [Hand on] is pressed once, the LCP
switches to Off mode. When pressed again,
the LCP switches to Hand on mode.
[4]
Hand Off/On w.
Same as [3] but a password is required (see
Passw.
[2]).
[9]
Enabled, ref = 0
0-41 [Off] Key on LCP
Option:
Function:
[0]
Disabled
Avoids accidental stop of the frequency
*
converter.
[1]
Enabled
*
[2]
Password Avoids unauthorised stop. If 0-41 [Off] Key on LCP is
included in the Quick Menu, then define the
password in 0-65 Quick Menu Password.
0-42 [Auto on] Key on LCP
Option:
Function:
[0]
Disabled
Avoid accidental start of the frequency converter
*
in Auto mode.
[1]
Enabled
*
[2]
Password Avoids unauthorised start in Auto mode. If
0-42 [Auto on] Key on LCP is included in the Quick
Menu, then define the password in 0-65 Quick
Menu Password.
0-43 [Reset] Key on LCP
Option:
Function:
[0]
Disabled
No effect when [Reset] is pressed. Avoids
*
accidental alarm reset.
[1]
Enabled
*
[2]
Password
Avoids unauthorised resetting. If
0-43 [Reset] Key on LCP is included in the
Quick Menu, then define the password in
0-65 Quick Menu Password.
FC 300 Programming Guide
0-43 [Reset] Key on LCP
Option:
[7]
[8]
3.2.6 0-5* Copy / Save
Copy parameter settings between set-ups and to/from the
LCP.
0-50 LCP Copy
Option:
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
This parameter cannot be adjusted while the motor is
running.
®
MG.33.MB.02 - VLT
is a registered Danfoss trademark
Function:
Enabled
Resets the drive without setting it in Off
without OFF
mode.
Password
Resets the drive without setting it in Off
without OFF
mode. A password is required when
pressing [Reset] (see [2]).
Function:
No copy
*
All to LCP
Copies all parameters in all set-ups
from the frequency converter memory
to the LCP memory.
All from LCP
Copies all parameters in all set-ups
from the LCP memory to the frequency
converter memory.
Size indep. from
Copy only the parameters that are
LCP
independent of the motor size. The
latter selection can be used to
programme several frequency
converters with the same function
without disturbing motor data.
File from MCO to
LCP
File from LCP to
MCO
Data from DYN to
LCP
Data from LCP to
DYN
3
3
31
Need help?
Do you have a question about the VLT AutomationDrive FC 300 and is the answer not in the manual?
Questions and answers