Danfoss VLT AutomationDrive FC 300 Programming Manual page 127

Hide thumbs Also See for VLT AutomationDrive FC 300:
Table of Contents

Advertisement

Parameter Descriptions
13-01 Start Event
Option:
[6]
Current limit
3
3
[7]
Out of current
range
[8]
Below I low
[9]
Above I high
[10] Out of speed
range
[11] Below speed low Below speed low [11] The output speed is
[12] Above speed
high
[13] Out of feedb.
range
[14] Below feedb. low Below feedb. Low [14] The feedback is
[15] Above feedb.
high
[16] Thermal warning Thermal warning [16] The thermal warning
[17] Mains out of
range
[18] Reversing
[19] Warning
[20] Alarm (trip)
[21] Alarm (trip lock)
[22] Comparator 0
126
FC 300 Programming Guide
Function:
Current limit [6] The motor current limit,
set in 4-18 Current Limit, has been
exceeded.
Out of current range [7] The motor current
is outside the range set in 4-18 Current
Limit.
Below I low [8] The motor current is lower
than set in 4-50 Warning Current Low.
Above I high [9] The motor current is
higher than set in 4-51 Warning Current
High.
Out of speed range [10] The speed is
outside the range set in 4-52 Warning
Speed Low and 4-53 Warning Speed High.
lower than the setting in 4-52 Warning
Speed Low.
Above speed high [12] The output speed is
higher than the setting in 4-53 Warning
Speed High.
Out of feedb. Range [13] The feedback is
outside the range set in 4-56 Warning
Feedback Low and 4-57 Warning Feedback
High.
below the limit set in 4-56 Warning
Feedback Low.
Above feedb. High [15] The feedback is
above the limit set in 4-57 Warning
Feedback High.
turns on when the temperature exceeds
the limit in the motor, the frequency
converter, the brake resistor or the
thermistor.
Mains out of range [17] The mains voltage
is outside the specified voltage range.
Reversing [18] The output is high when
the frequency converter is running
counter clockwise (the logical product of
the status bits "running" AND "reverse").
Warning [19] A warning is active.
Alarm (trip) [20] A (trip) alarm is active.
Alarm (trip lock) [21] A (Trip lock) alarm is
active.
Comparator 0 [22] Use the result of
comparator 0.
MG.33.MB.02 - VLT
13-01 Start Event
Option:
[23] Comparator 1
[24] Comparator 2
[25] Comparator 3
[26] Logic rule 0
[27] Logic rule 1
[28] Logic rule 2
[29] Logic rule 3
[33] Digital input DI18 Digital input DI18 [33] Use the result of
[34] Digital input DI19 Digital input DI19 [34] Use the result of
[35] Digital input DI27 Digital input DI27 [35] Use the result of
[36] Digital input DI29 Digital input DI27 [35] Use the result of
[37] Digital input DI32 Digital input DI32 [37] Use the result of
[38] Digital input DI33 Digital input DI33 [38] Use the result of
[39] Start command
[40] Drive stopped
[41] Reset Trip
[42] Auto-reset Trip
[43] Ok key
[44] Reset key
[45] Left key
[46] Right key
[47] Up key
[48] Down key
[50] Comparator 4
[51] Comparator 5
®
is a registered Danfoss trademark
Function:
Comparator 1 [23] Use the result of
comparator 1.
Comparator 2 [24] Use the result of
comparator 2.
Comparator 3 [25] Use the result of
comparator 3.
Logic rule 0 [26] Use the result of logic rule
0.
Logic rule 1 [27] Use the result of logic rule
1.
Logic rule 2 [28] Use the result of logic rule
2.
Logic rule 3 [29] Use the result of logic rule
3.
digital input 18.
digital input 19.
digital input 27.
digital input 29.
digital input 32.
digital input 33.
Start command [39] A start command is
issued.
Drive stopped [40] A stop command ( Jog,
Stop, Qstop, Coast) is issued – and not
from the SLC itself.
Reset Trip [41] A reset is issued
Auto-reset Trip [42] An Auto reset is
performed.
OK key [43] The [OK] key is pressed.
Reset key [44] The [Reset] key is pressed.
Left key [45] The [◄] key is pressed.
Right key [46] The[►] key is pressed.
Up key [47] The [
] key is pressed.
Down key [48] The [
] key is pressed.
Comparator 4 [50] Use the result of
comparator 4.
Comparator 5 [51] Use the result of
comparator 5.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AutomationDrive FC 300 and is the answer not in the manual?

Questions and answers

Table of Contents