Consecutive error monitor
a
To use the Consecutive error monitor type, click the Consecutive error monitor toggle key so that it is
in the ON position.
b
In the Failover fail count field, enter an integer between 3 and 65535 for the number of times a retry
ping should fail before the router fails over to the next WAN interface.
c
In the Failback success count field, enter an integer between 3 and 65535 for the number of times a
periodic ping should succeed before the router fails back to the higher priority interface.
d
Click the Save button when you have finished entering your settings.
Periodic ratio monitor
a
To use the Periodic ratio monitor, set the Fail/success count field to 0.
b
In the Monitor total count field, enter an integer between 3 and 65535 for the number of previous
pings to consider for failover and failback.
c
If you do not wish to use the periodic ratio monitor, set this to 0. In the Failover fail count field, enter
the number of pings out of the total count that must fail before the router fails over to the next highest
priority WAN interface.
d
In the Failback success count field, enter the number of pings out of the total count that must succeed
before the router fails back to the higher priority WAN interface.
The Active WAN interfaces are displayed once again, this time showing that the Ping monitor type is in use for the
interface.
Click the Save button to save the settings. The WAN failover configuration is complete.