Connection Device Information

Set the information of the connected device.
Item
Description
CC-Link IE
Sets the CC-Link IE TSN Class of connected devices.
TSN Class
Setting
TSN HUB
Sets whether to use the TSN switching hub or not.
Setting
Precautions
• To connect a TSN switching hub to the structure of a mixture of CC-Link IE TSN Class B and CC-Link IE TSN Class A
devices, set "TSN HUB Setting" to "Use TSN HUB".
• If a TSN switching hub is connected with "TSN HUB Setting" set to "Not to Use TSN HUB", device stations may not perform
data link.
• If a TSN switching hub is used for connection in a star topology with "TSN HUB Setting" set to "Not to Use TSN HUB",
device stations connected to the TSN switching hub do not perform data link. Also, the error "Connection configuration
error" (error code: 1806H) occurs in the master station.

Device Station Setting

Set items related to the device station.
Item
Description
Disconnection
Set the number of consecutive communication failures until a device station is considered disconnected.
Detection
Setting
Precautions
The disconnection detection setting does not necessarily guarantee that the disconnection is performed according to the
number of times set. When disconnection is detected, a bit of the disconnected station in 'Data link status of each station'
(SW00B0 to SW00B7) turns on. However, the time required this may be at least four times the time required for the number of
consecutive communication failures set in the disconnection detection setting.
5 PARAMETER SETTINGS
104
5.3 Basic Settings
Setting range
• CC-Link IE TSN Class B Only
• Mixture of CC-Link IE TSN
Class B/A or CC-Link IE TSN
Class A Only
(Default: CC-Link IE TSN Class
B Only)
• Not to Use TSN HUB
• Use TSN HUB
(Default: Not to Use TSN HUB)
Setting range
• 2 times
• 4 times
• 8 times
(Default: 4 times)