Relay Switching Wiring - Mitsubishi Electric R60AD8-G User Manual

Melsec iq-r series channel isolated analog-digital converter module
Table of Contents

Advertisement

Relay switching wiring

Relay switching wiring is as follows.
Cable connector
Terminal block
Connection to relays
24VDC
For available terminal modules and special cables, refer to the following.
Page 240 Terminal module for the RY40PT5B
Use an external power supply (24VDC) that satisfies the following conditions.
• The overvoltage protection function is available.
• The output voltage does not exceed 35VDC in single fault state.
Cable
YF(-)
YF(+)
YE(-)
YE(+)
YD(-)
YD(+)
·
Y2(-)
Y2(+)
Y1(-)
Y1(+)
Y0(-)
Y0(+)
DC0V
DC24V
Terminal module
Connector number
Terminal
block
1
Y0
20
2
Y1
18
3
Y2
16
14
4
Y3
5
6
7
8
9
10
11
12
13
14
15
YE
16
YF
1
17
+24V(COM)
2
3
18
0V
4
RY40PT5B
9 INSTALLATION AND WIRING