Mitsubishi Electric R60AD8-G User Manual page 196

Melsec iq-r series channel isolated analog-digital converter module
Table of Contents

Advertisement

CH1 Loading interrupt enable/disable setting
Set whether to enable or disable the logging read function.
For details on the logging function, refer to the following.
Page 61 Logging Function
Setting value
0
1
• If a value other than the above is set, a read interrupt enable/disable setting range error (error code: 1D8H) occurs.
Logging cannot be performed.
• When CH1 Logging read enable/disable setting (Un\G544) is set to Enable (0), an interrupt is generated and sent to the
CPU module by setting a read pointer each time an amount equivalent to the logging read points setting value is logged.
■Buffer memory address
The following shows the buffer memory address of this area.
• CH Loading interrupt enable/disable setting
CH1
CH2
CH3
544
744
944
• CH Loading interrupt enable/disable setting (in Q compatible mode)
CH1
CH2
CH3
1200
1201
1202
■Enabling the setting
Turn on and off 'Operating condition setting request' (Y9).
■Default value
The default value is Disable (1) for all channels.
The interrupt pointer to be used is preset but can be changed. To change the interrupt pointer, set the
corresponding interrupt pointer with the engineering tool.
APPX
194
Appendix 3 Buffer Memory Areas
CH4
CH5
CH6
CH7
1144
1344
1544
1744
CH4
CH5
CH6
CH7
1203
1204
1205
1206
Setting content
Enable
Disable
CH8
CH9
CH10
CH11
1944
2144
2344
2544
CH8
CH9
CH10
CH11
1207
CH12
CH13
CH14
CH15
2744
2944
3144
3344
CH12
CH13
CH14
CH15
CH16
3544
CH16