Range reference table
The following describes the range reference tables used for saving and restoring offset/gain values.
■Factory default setting
The following describes the buffer memory addresses of the factory default setting.
R60AD8-G: CH1 Factory default setting offset value (L) (Un\G4004) to CH8 Factory default setting gain value (H) (Un\G4035)
R60AD16-G: CH1 Factory default setting offset value (L) (Un\G4004) to CH16 Factory default setting gain value (H)
(Un\G4067)
• For the R60AD8-G
Address (decimal)
CH1
CH2
CH3
4004
4008
4012
4005
4009
4013
4006
4010
4014
4007
4011
4015
*1 The reference values differ depending on the setting of Save data type setting (Un\G4002) (voltage or current).
• For the R60AD16-G
Address (decimal)
CH1
CH2
CH3
4004
4008
4012
4005
4009
4013
CH9
CH10
CH11
4036
4040
4044
4037
4041
4045
CH1
CH2
CH3
4006
4010
4014
4007
4011
4015
CH9
CH10
CH11
4038
4042
4046
4039
4043
4047
*1 The reference values differ depending on the setting of Save data type setting (Un\G4002) (voltage or current).
■User range setting
The following describes the buffer memory addresses of the user range setting.
R60AD8-G: CH1 User range setting offset value (L) (Un\G4036) to CH8 User range setting gain value (H) (Un\G4067)
R60AD16-G: CH1 User range setting offset value (L) (Un\G4068) to CH16 User range setting gain value (H) (Un\G4131)
Offset/gain value
Current
*1 This value is stored in User range setting offset value by default of the R60AD8-G or R60ADI6-G.
*2 This value is stored in User range setting gain value by default of the R60AD8-G or R60ADI6-G.
1 FUNCTIONS
94
1.16 Backing up, Saving, and Restoring Offset/Gain Values
CH4
CH5
CH6
4016
4020
4024
4017
4021
4025
4018
4022
4026
4019
4023
4027
CH4
CH5
CH6
4016
4020
4024
4017
4021
4025
CH12
CH13
CH14
4048
4052
4056
4049
4053
4057
CH4
CH5
CH6
4018
4022
4026
4019
4023
4027
CH12
CH13
CH14
4050
4054
4058
4051
4055
4059
*1
4mA
*2
20mA
Description
CH7
CH8
4028
4032
Factory default
4029
4033
setting offset
value
4030
4034
Factory default
4031
4035
setting gain
value
Description
CH7
CH8
Factory default
setting offset
4028
4032
value
4029
4033
CH15
CH16
4060
4064
4061
4065
CH7
CH8
Factory default
setting gain
4030
4034
value
4031
4035
CH15
CH16
4062
4066
4063
4067
Reference value (hexadecimal)
875E29H
A4D6CDH
Save data
Analog
Reference value
type
value
(hexadecimal)
*1
setting
Voltage
0V
800000H
specification
Current
0mA
800000H
specification
Voltage
10V
C92492H
specification
Current
20mA
A4D6CDH
specification
Save data
Analog
Reference value
type
value
(hexadecimal)
*1
setting
Voltage
0V
800000H
specification
0mA
Current
specification
Voltage
10V
C92492H
specification
20mA
A4D6CDH
Current
specification

Hide quick links: