Latest address of alarm history
Among Alarm history  (Un\G3760 to Un\G3999), a buffer memory address which stores the latest alarm code is stored.
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
Latest address of alarm history
Latest address of alarm history (in Q compatible
mode)
Interrupt factor detection flag [n]
The detection status of the interrupt factor is stored.
Monitor value
0
1
When an interrupt factor occurs, an interrupt request is sent to the CPU module at the same time as 'Interrupt factor detection
flag [n]' (Un\G4 to Un\G19) is turned to Interrupt factor (1).
"n" indicates an interrupt setting number. (n = 1 to 16)
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
1
Interrupt factor detection flag
4
[n]
Interrupt factor detection flag
4000
[n] (in Q compatible mode)
Alert output flag (Process alarm upper limit)
The upper limit alarm of the process alarm can be checked for each channel.
b15 b14 b13 b12 b11 b10 b9
CH16 CH15 CH14 CH13 CH12 CH11 CH10 CH9
• 0: Normal, 1: Alarm ON
• b8 to b15 of the R60AD8-G are fixed to 0.
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
Alert output flag (Process alarm upper limit)
■Alert output flag status
• When the value is out of the range specified in the process alarm upper upper limit value, Alarm ON (1) is stored in 'Alert
output flag (Process alarm upper limit)' (Un\G36) corresponding to each channel.
• When an alert is detected in any channel where the A/D conversion and the alert output setting (Process alarm) are
enabled, 'Alert output signal' (X8) also turns on.
■Clearing Alert output flag
• When the digital operation value returns within the setting range, the flag is automatically cleared.
• When 'Operating condition setting request' (Y9) is turned on and off, the flag is cleared.
CH
CH
CH
CH
1
2
3
4
3
3751
2
3
4
5
6
5
6
7
8
9
4001
4002
4003
4004
4005
b8
b7
b6
b5
b4
b3
b2
CH8
CH7
CH6
CH5
CH4
CH3
CH
CH
CH
CH
1
2
3
4
36
CH
CH
CH
CH
CH
5
6
7
8
9
Description
No interrupt factor
Interrupt factor
7
8
9
10
10
11
12
13
4006
4007
4008
4009
b1
b0
CH2
CH1
CH
CH
CH
CH
CH
5
6
7
8
9
CH
CH
CH
CH
CH
CH
10
11
12
13
14
15
11
12
13
14
15
14
15
16
17
18
4010
4011
4012
4013
4014
CH
CH
CH
CH
CH
CH
10
11
12
13
14
15
APPX
Appendix 3 Buffer Memory Areas
CH
16
16
19
4015
A
CH
16
147

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R60ad16-g

Table of Contents