Maximum value/minimum value reset completed flag
Maximum value/minimum value reset completed flag (XD) turns on after the maximum and minimum values stored in 'CH1
Maximum value' (Un\G404) and 'CH1 Minimum value' (Un\G406) are reset by turning on and off 'Maximum value/minimum
value reset request' (YD).
'CH1 Maximum value' (Un\G404)
'CH2 Minimum value' (Un\G406)
'Maximum value/minimum value
reset request' (YD)
'Maximum value/minimum value
reset completed flag' (XD)
■Device number
The following shows the device number of this input signal.
Signal name
Maximum value/minimum value reset
completed flag
A/D conversion completed flag
A/D conversion completed flag (XE) turns on when all conversion enabled channels are converted.
■Device number
The following shows the device number of this input signal.
Signal name
A/D conversion completed flag
Error flag
'Error flag' (XF) turns on when an error occurs.
Turn on and off 'Error clear request' (YF) to clear 'Latest error code' (Un\G0) and 'Latest alarm code' (Un\G2).
'Latest error code' (Un\G0)
'Error flag' (XF)
'Error clear request' (YF)
■Device number
The following shows the device number of this input signal.
Signal name
Error flag
APPX
122
Appendix 2 I/O Signals
Controlled by the A/D converter module
Controlled by the program
Maximum value
Minimum value
ON
ON
CH1 to CH16
XD
CH1 to CH16
XE
Controlled by the A/D converter module
Controlled by the program
Error code
0
ON
CH1 to CH16
XF
0
0
OFF
OFF
0
OFF
ON
OFF