Before charging batteries, read the "Battery and Charger Handling Precautions".
Charge
Plug
Connector for battery charger
This is the connector for charging the NiMH
battery HT5F1800B that is installed in the
transmitter. Do not use any other chargers except
the attached special charger corresponding to
NiMH battery.
Warning
Do not connect any other chargers except
the special charger to this charging
connector.
How to charge the NiMH battery HT5F1800B
for the transmitter
Danger
The NiMH battery HT5F1800B is only for
your T12K. Do not use this battery for other
equipment.
Be sure to use the attached special charger
to charge the battery.
[Method of charging battery]
Special charger
*Connect to AC outlet
specified.
Receiver Batt.
Charging display
1. Connect the special charger to the wall
socket (AC outlet).
2 . C o n n e c t t h e c o n n e c t o r s t o t h e T 1 2 K
charging jack.
*Turn off the transmitter while charging the battery.
3. Remove the battery after 15 hours.
*Battery charging will not automatically stop. Remove the
battery and transmitter from the charger and remove the
charger from the wall socket.
*It is recommended to reactivate the battery by cycling
several times if the battery has not been used for a long
period.
*In the case of NiMH/NiCd batteries, you may find poor
performance of the battery if you have used the battery
only for a short period or if you repeat charging while the
battery is not fully discharged. It is suggested to discharge
the battery to the recommended level after use. It is also
recommended to charge the battery just before use.
Transmitter Batt.
Charging display
To T12K charge
connector
<Before Use>