SENSOR
This screen registers the telemetry sensors used
with the transmitter. When only one of a certain
type of sensor is used, this setting is unnecessary
and the sensor can be used by simply connecting it
to the S.BUS2 port of the transmitter.
When using 2 or more of the same kind of
sensor, they must be registered here.
RTN
HOME/EXIT
RETURN
*3 slots of altitude sensor are used.
*8 slots of GPS sensor are used.
< Assignable slot >
Sensor
number of slots
SBS-01T/TE/TE(TEMP)
SBS-01RM/RO/RB(RPM)
SBS-01V(Voltage)
SBS-01A/02A(Altitude)
SBS-01C
SBS-01S(S.BUS servo)
SBS-01G/02G(GPS)
Robbe TEMP125-F1713
Robbe VARIO-F1712
Robbe VARIO-F1672
Robbe CURR-F1678
Robbe GPS-F1675
Robbe True Airspeed
Sensor 450
Castle-TL0
Kontronik
PowerBox
<Functions of Linkage Menu>
122
*Altimeter, GPS, and other sensors that display a large amount of data require multiple slots.
*Depending on the type of sensor, the slot numbers that can be allocated may be limited.
The required
The number which can be used as a start slot
1 slot
1 slot
1 , 2 , 3 , 4 , 5 , 6 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 6 , 1 7 , 1 8 , 1 9 ,
2 slots
2 0 , 2 1 , 2 2 , 2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9 , 3 0
1 , 2 , 3 , 4 , 5 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 6 , 1 7 , 1 8 , 1 9 , 2 0 , 2 1 ,
3 slots
1 , 2 , 3 , 4 , 5 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 6 , 1 7 , 1 8 , 1 9 , 2 0 , 2 1 ,
3 slots
6 slots
8 slots
1 slot
1 , 2 , 3 , 4 , 5 , 6 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 6 , 1 7 , 1 8 , 1 9 ,
2 slots
2 0 , 2 1 , 2 2 , 2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9 , 3 0
1 , 2 , 3 , 4 , 5 , 6 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 6 , 1 7 , 1 8 , 1 9 ,
2 slots
2 0 , 2 1 , 2 2 , 2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9 , 3 0
1 , 2 , 3 , 4 , 5 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 6 , 1 7 , 1 8 , 1 9 , 2 0 , 2 1 ,
3 slots
8 slots
1 slot
8 slots
8 slots
16 slots
Servos are classified by CH, but sensors are
classified in units called "slot". There are slots
from No. 1 to No. 31.
Altitude sensors, GPS sensors and other data
sensor units may use multiple slots.
Using a sensor which uses two or more slots,
the required number of slots is automatically
assigned by setting up a start slot.
When 2 or more of the same kind of sensor are
used, the sensors themselves must allocate unused
slots and memorize that slot.
<Push Dial>
1 ∼ 31
1 ∼ 31
2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9
2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9
1 , 2 , 8 , 9 , 1 0 , 1 6 , 1 7 , 1 8 ,
2 4 , 2 5 , 2 6
8 , 1 6 , 2 4
1 ∼ 31
2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9
8 , 1 6 , 2 4
1 ∼ 31
8 , 1 6 , 2 4
8 , 1 6 , 2 4
8 , 1 6