Model and
Support
Materials

UV Lamps

DOC08010 Rev. A (DRAFT 1)
Model and support materials are made of chemical substances. Although
precautions must be taken when handling these materials directly, all
model and support materials used by the Stratasys system are handled in
sealed cartridges. Normally, operators of the printer should never be
directly exposed to hazardous materials. In the unlikely event of a leak or
spill, follow the instructions that are included with the printing material
cartridge used.
Store model and support materials indoors, in a dry area with adequate
ventilation, between 16 27 degrees Celsius (60 81 degrees Fahrenheit).
Never expose them to flames, heat, sparks, or direct sunlight.
Keep model and support materials away from areas where food and
drink are stored, prepared and consumed.
Uncured printing material is considered a hazardous substance,
requiring certain precautions when directly handling it. To prevent skin
irritation, wear neoprene or nitrile gloves. If there is any chance that
model and support materials might splash into the eyes, wear safety
goggles. Prolonged direct contact with printing materials can cause an
allergic reaction.
When handling UV cured models that may not be completely cured on
the surface, common latex gloves are adequate.
To prevent respiratory irritation, ventilate areas where model and
support materials are used. If the printer is not equipped with an
exhaust duct, the room ventilation system should replace the air at least
20 times per hour.
Clean up model material and support material spills with disposable
towels or other absorbent, non reusable material, such as sawdust or
activated charcoal. Rinse the spill area with denatured or isopropyl
alcohol (IPA), followed by soap and water. Dispose of the absorbent
material in accordance with local regulations.
Do not wash contaminated clothing at home; clothing should be
professionally laundered.
Dispose of contaminated shoes, belts and other leather items in
accordance with any applicable regulations. Absorbed printing
material may re expose the user when these items are worn.
UV lamps used by the printer to cure printing materials contain a small
amount of mercury. In the unlikely event of lamp breakage, avoid inhaling
mercury vapor, and ventilate the room. If the lamp ruptures (breaks)
during operation, leave the room and ventilate it thoroughly (for about 30
minutes).
Use protective gloves to prevent contact with mercury and other lamp
components. Carefully remove spilled mercury with a method that
prevents the generation of mercury vapor, such as a syringe, packing tape
or paper.
Place the broken lamp, mercury and contaminated materials in an air tight,
non metallic container. Dispose of the container in accordance with
applicable regulations.